Transients and Stability: Electrical Systems Study with PID Tuning Methods Controller

Authors

  • Soumia Djelaila LSETER Laboratory, Nour Bachir University Centre, El-Bayadh, Algeria
  • Ali Abderrazak Tadjeddine LSETER Laboratory, Nour Bachir University Centre, El-Bayadh, Algeria
  • Linda Bellal LSETER Laboratory, Nour Bachir University Centre, El-Bayadh, Algeria
  • Asma Ouardas LSETER Laboratory, Nour Bachir University Centre, El-Bayadh, Algeria
  • Ridha Ilyas Bendjillali LSETER Laboratory, Nour Bachir University Centre, El-Bayadh, Algeria
  • Mohammed Sofiane Bendelhoum LSETER Laboratory, Nour Bachir University Centre, El-Bayadh, Algeria

DOI:

https://doi.org/10.25728/assa.2026.2026.3.2037

Keywords:

PID Control, Transient regimes, Steady-State Regime, Robustness, Ziegler-Nichols Method, Control System, Performance Indices

Abstract

The transient response of electrical circuits often exhibits undesirable oscillations that hinder precise voltage regulation. This paper presents a comprehensive simulation-based study of a series RLC circuit and a buck converter controlled by proportional-integral-derivative (PID) controllers. Four tuning strategies are compared: manual tuning, Ziegler-Nichols, particle swarm optimization (PSO), and genetic algorithm (GA). Performance is assessed using time-domain metrics (overshoot, settling time, IAE, ITAE) and frequency-domain tools (Bode, Nyquist, sensitivity functions). Robustness is evaluated through parameter variations (R, L, C, ω₀, ζ), dynamic setpoint tracking, external disturbances, and Monte Carlo analysis (±20% component tolerances). The open-loop RLC circuit exhibits 80% overshoot and a settling time of 0.382 s. Manual PID tuning reduces overshoot to 13.7%, settling time to 0.024 s, and eliminates steady-state error. Ziegler-Nichols yields zero overshoot but an extremely slow response (rise time 0.617 s). PSO and GA produce the fastest rise times (5.6 ms) but increase overshoot to ≈21% and reduce phase margins to ≈8°, indicating fragility to model uncertainties. The manual PID demonstrates robust performance under all tested variations and maintains acceptable metrics under Monte Carlo simulation (mean overshoot 13.1%). For the buck converter, an optimized PID reduces the IAE by a factor of 2.5 compared to manual tuning, with identical control energy. This study confirms that the choice of PID tuning involves a clear trade-off between speed, overshoot, robustness, and control effort. Manual tuning offers the best balance for the RLC circuit, while optimization is highly beneficial for fast power electronics applications.

Downloads

Published

2026-10-01

How to Cite

Transients and Stability: Electrical Systems Study with PID Tuning Methods Controller. (2026). Advances in Systems Science and Applications, 2026(3), 92-107. https://doi.org/10.25728/assa.2026.2026.3.2037